- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources3
- Resource Type
-
0000000003000000
- More
- Availability
-
12
- Author / Contributor
- Filter by Author / Creator
-
-
Neves, Manoela (3)
-
Zakerzadeh, Rana (3)
-
Aparnasai_Reddy, Gayathri (1)
-
Delaney, Norah (1)
-
McCollum, Isabella (1)
-
Meng, Wilson S (1)
-
Niyingenera, Anitha (1)
-
Throop, Alexis (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Microfluidic devices offer well-defined physical environments that are suitable for effective cell seeding and in vitro three-dimensional (3D) cell culture experiments. These platforms have been employed to model in vivo conditions for studying mechanical forces, cell–extracellular matrix (ECM) interactions, and to elucidate transport mechanisms in 3D tissue-like structures, such as tumor and lymph node organoids. Studies have shown that fluid flow behavior in microfluidic slides (µ-slides) directly influences shear stress, which has emerged as a key factor affecting cell proliferation and differentiation. This study investigates fluid flow in the porous channel of a µ-slide using computational fluid dynamics (CFD) techniques to analyze the impact of perfusion flow rate and porous properties on resulting shear stresses. The model of the µ-slide filled with a permeable biomaterial is considered. Porous media fluid flow in the channel is characterized by adding a momentum loss term to the standard Navier–Stokes equations, with a physiological range of permeability values. Numerical simulations are conducted to obtain data and contour plots of the filtration velocity and flow-induced shear stress distributions within the device channel. The filtration flow is subsequently measured by performing protein perfusions into the slide embedded with native human-derived ECM, while the flow rate is controlled using a syringe pump. The relationships between inlet flow rate and shear stress, as well as filtration flow and ECM permeability, are analyzed. The findings provide insights into the impact of shear stress, informing the optimization of perfusion conditions for studying tissues and cells under fluid flow.more » « lessFree, publicly-accessible full text available June 17, 2026
-
Zakerzadeh, Rana; McCollum, Isabella; Neves, Manoela (, International Journal of Heat and Mass Transfer)Free, publicly-accessible full text available March 1, 2026
-
Throop, Alexis; Neves, Manoela; Zakerzadeh, Rana (, Computational and Structural Biotechnology Journal)The mechanisms of abdominal aortic aneurysm (AAA) formation and rupture are controversial in the literature. While the intraluminal thrombus (ILT) plays a crucial role in reducing oxygen flux to the tissue and therefore decreasing the aortic wall strength, other physiological parameters such as the vasa vasorum (VV) oxygen flow and its consumption contribute to altered oxygenation responses of the arterial tissue as well. The goal of this research is to analyse the importance of the aforementioned parameters on oxygen delivery to the aneurysmal wall in a patient-specific AAA. Numerical simulations of coupled blood flow and mass transport with varying levels of VV concentration and oxygen reaction rate coefficient are performed. The hypoperfusion of the adventitial VV and high oxygen consumption are observed to have critical effects on reducing aneurysmal tissue oxygen supply and can therefore exacerbate localized oxygen deprivation.more » « less
An official website of the United States government
